Repository logo
  • English
  • Deutsch
  • Español
  • Français
  • Log In
    New user? Click here to register.Have you forgotten your password?

  • English
  • Deutsch
  • Español
  • Français
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
  • Communities & Collections
  • Research Outputs
  • Fundings & Projects
  • Researchers
  • Statistics
  1. Home
  2. Current Research Information System UV
  3. Publicaciones
  4. A New And Efficient High-Performance Electrochemical Glucose Sensor Based On A Metallopolymer Derived From A Cobaltate (Iii) Schiff Base Complex
 
  • Details
Options

A New And Efficient High-Performance Electrochemical Glucose Sensor Based On A Metallopolymer Derived From A Cobaltate (Iii) Schiff Base Complex

Date Issued
2020-11-21
Author(s)
Hernández, Loreto  
Facultad de Ciencias  
Darío M. González
Jocelyn Oyarce
Andrea Alfaro
Néstor Novoa
Jonathan Cisterna
Iván Brito
David Carrillo
Carolina Manzur
DOI
10.1016/j.synthmet.2020.116633
WoS ID
WOS:000603540400007
Abstract
Through a simple and effective reaction of the cobalt (II) acetate tetrahydrate with a new ONO-tridentate Schiff base ligand (L1), which contains a thiophenyl group, a mono-anionic complex of formula: [{4-Th-C6H4-C(O)CH-C(CH3)=N-C6H4-2-O}2Co]-[Bu4N]+ (C1) was isolated. Spectroscopic tools (1H and 13C NMR, FT-IR) and the crystal structure revealed that C1 consists of a mononuclear six-coordinate anionic Co(III) center with a pseudo-octahedral geometry, and one tetrabutylammonium counterion to satisfy the negative charge of the coordination entity [CoIII(L1)2]-. Electropolymerization of C1 produces a conductive metallopolymer deposit on fluorine-doped tin oxide (FTO) electrodes, which acts as an efficient glucose sensor, showing a linear amperometric response for glucose within a concentration range of 1.97 × 10 −7 M to 3.88 × 10−6 M (R2 = 0.993), limit of detection (LOD) of 9.27 × 10−7 M and limit of quantification (LOQ) of 9.24 × 10−6 M. This electrochemical sensor, which exhibit excellent reproducibility in the manufacturing process, was stable in environmental conditions and showed good reproducibility of the measurements for two weeks. In addition, the metallopolymer deposit was characterized by electrochemical techniques (cyclic voltammetry) and SEM microscopy.
Subjects

Condensed Matter Phys...

Electronic, Optical A...

Materials Science, Mu...

Materials Chemistry

Mechanical Engineerin...

Mechanics Of Material...

Metals And Alloys

Physics, Condensed Ma...

Polymer Science

OCDE Subjects

Natural Sciences::Phy...

Quartile (Date Issued)
Q2
License
acceso restringido

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback

Hosting & Support by

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science