  4. Effect Of Inhalation Flow Rate On Mass-Based Plume Geometry Of Commercially Available Suspension Pmdis
 
  • Details
Options

Effect Of Inhalation Flow Rate On Mass-Based Plume Geometry Of Commercially Available Suspension Pmdis

Journal
The AAPS Journal
Date Issued
2018-07-12
Author(s)
Moraga, Daniel  
Facultad de Farmacia  
Eli Eshaghian
Albert Shaver
Hugh D. C. Smyth
DOI
10.1208/s12248-018-0241-6
WoS ID
WOS:000438727300001
Abstract
Although high-speed laser imaging is the current standard to characterize the plume angle of suspension-based pressurized metered dose inhalers (pMDIs), this method is limited by the inability to identify the drug content in a droplet and simulate inhalation flow. The Plume Induction Port Evaluator (PIPE) is a modified induction port for cascade impactors that allows for the calculation of the angle of a plume based on direct drug mass quantification rather than indirect droplet illumination under airflow conditions. The objective of this study was to investigate the use of the PIPE apparatus to evaluate the effect of airflow on the Mass Median Plume Angle (MMPA) of commercially available suspension-based pMDIs (Ventolin® HFA, ProAir® HFA, and Proventil® HFA). Deposition patterns within PIPE were log-normally distributed allowing for the calculation of the MMPA for the three suspension products. Mass-based plume angles were significantly smaller (narrower angle) when inhalation airflow was used compared to no flow conditions (reduction of MMPA was 8, 16, and 13% for Ventolin® HFA, ProAir® HFA, and Proventil® HFA, respectively). Additionally, new parameters for characterizing plume geometry were calculated (MMPA ex-actuator and plume orientation). Mass-based plume angles of the suspension-based pMDI formulations were highly reproducible and demonstrated the effect of inhalation flow rate. These results suggest that plume geometry tests should be evaluated under flow conditions which is not possible using current methodologies. [Figure not available: see fulltext.].
Subjects

Pharmacology And Phar...

Pharmaceutical Scienc...

OCDE Subjects

Medical And Health Sc...

Quartile (Date Issued)
Q2
License
acceso restringido