Repository logo
  • English
  • Deutsch
  • Español
  • Français
  • Log In
    New user? Click here to register.Have you forgotten your password?

  • English
  • Deutsch
  • Español
  • Français
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
  • Communities & Collections
  • Research Outputs
  • Fundings & Projects
  • Researchers
  • Statistics
  1. Home
  2. Current Research Information System UV
  3. Publicaciones
  4. Disinfection Of Human Amniotic Membrane Using A Hydrodynamic System With Ozonated Water
 
  • Details
Options

Disinfection Of Human Amniotic Membrane Using A Hydrodynamic System With Ozonated Water

Date Issued
2022-01-06
Author(s)
Buendía, Débora  
Facultad de Ingeniería  
San Martín, Sebastián  
Facultad de Medicina  
Sílvia Móbille Awoyama
Henrique Cunha Carvalho
Túlia de Souza Botelho
Sandra Irene Sprogis dos Santos
Renato Amaro Zângaro
Carlos José de Lima
Adriana Barrinha Fernandes
DOI
10.1080/01919512.2021.2022452
WoS ID
WOS:000739727700001
Abstract
Human amniotic membrane (hAM) has a great potential in regenerative medicine as it can be disinfected, preserved, and stored. The present study evaluated a hydrodynamic system that uses ozonated water for disinfecting hAM and assessed possible morphological alterations using histological analysis and scanning electron microscopy (SEM). hAM fragments were experimentally contaminated with Staphylococcus aureus (103 CFU/mL) and submitted to disinfection processes for 5, 10 and 15 minutes (1.95, 3.9 and 5.85 mg/cm2 (O3), respectively). The results of the water microbiological analysis showed that no microbial growth was detected in all water samples. The hAM surface monitoring with swab method and the analysis of fragment inoculated directly into the culture media revealed that no microbial growth was detected after 10 and 15 minutes. The SEM and histological analysis of hAM revealed that morphological alterations in the epithelium began after 10 minutes 3.9 mg/cm2 (O3) of the disinfection process, and significant changes in the epithelial cells were observed after 15 minutes (5.85 mg/cm2 (O3)). These findings indicates that the structural integrity of hAM was maintained during the process and suggest that the technique is a promising system to disinfect this biological material.
Subjects

Environmental Chemist...

Environmental Enginee...

OCDE Subjects

Natural Sciences::Phy...

Quartile (Date Issued)
Q3
License
acceso restringido

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback

Hosting & Support by

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science