Repository logo
  • English
  • Deutsch
  • Español
  • Français
  • Log In
    New user? Click here to register.Have you forgotten your password?

  • English
  • Deutsch
  • Español
  • Français
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
  • Communities & Collections
  • Research Outputs
  • Fundings & Projects
  • Researchers
  • Statistics
  1. Home
  2. Current Research Information System UV
  3. Publicaciones
  4. A Low-Cost Device for Measuring Non-Nutritive Sucking in Newborns
 
  • Details
Options

A Low-Cost Device for Measuring Non-Nutritive Sucking in Newborns

Journal
Sensors
Date Issued
2025-08-15
Author(s)
Lobos, Sebastián  
Facultad de Ingeniería  
Spencer, Eyleen  
Facultad de Ingeniería  
Reyes, Pablo  
Facultad de Ingeniería  
Alejandro Weinstein
Jana Stojanova
Felipe Retamal-Walter
DOI
10.3390/s25165080
Abstract
<jats:p>Non-nutritive sucking (NNS) is an instinctive behavior in newborns, consisting of two stages: sucking and expression. It plays a critical role in preparing the infant for oral feeding. In neonatal and pediatric units, NNS assessment is routinely performed to determine feeding readiness. However, these evaluations are often subjective and rely heavily on the clinician’s experience. While other medical devices that support the development of NNS skills exist, they are not specifically designed for the comprehensive assessment of NNS, and their high cost limits accessibility for many hospitals and tertiary care units globally. This paper presents the development and pilot testing of a low-cost, portable device and accompanying software for assessing NNS in newborns hospitalized in neonatal care units. Methods: The device uses force-sensitive resistors to capture expression pressure and a differential pressure sensor to measure NNS. Data were acquired through the analog–digital converter of a microcontroller and transmitted via Bluetooth for real-time graphical analysis. Pilot testing was conducted with six hospitalized preterm newborns, measuring intensity, number of bursts, and sucks per burst. Results demonstrated that the system reliably captures both stages of NNS. Significance: This device provides an affordable, portable solution to support clinical decision-making in clinical units, facilitating accurate, objective monitoring of feeding readiness and developmental progression.</jats:p>

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback

Hosting & Support by

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science